CARBON DIOXIDE (CO2)
Carbon dioxide is an effective fire suppression agent applicable to a wide range of fire hazards. Carbon dioxide works quickly, with no Residual clean-up associated with a system discharge which translates Into minimal business interruption.AGENT – HEPTA FLUO ROPROPANE (FM-200(R))
The extinguishing agent used in Rotarex Pre-engineered Fire-Suppression systems Is Heptafluoropropane, more commonly known by its ASHRAE designation: FM-200®.FM-200® is a colorless, odorless, liquefied compressed gas.
(See the Physical Properties Table). It is stored as a liquid, but dispensed into the hazard As a colorless, electrically- nonconduotive, gaseous vapor due to it’s relatively low boiling point.
FM-200® has been tested and verified to be safe for use in occupied Spaces when used as specified in the U.S. EPA Significant New Alternative Policy (SNAP) rules. Tests have proven that exposure to FM-200® is safe and effective in extinguishing fires at low concentrations; most of which are well below the EPA’s Maximum exposure levels.
FM-200® is approved for use in occupied areas up to 10.5% concentration by volume with a mandated egress time of 5 minutes or less.
HFC-227 ea
• Inert on people & safe on environment• lower design concentration, safe and non-toxic
• Active on fire with complete extinguishment capability designed to fully discharge within seconds.
• three dimensional to knock down fires in hidden spaces.
• Ability to recover quickly from business disruption.
• No cost of down time.
• Zero Ozone depletion potential.
• Superior to water and dry chemicals.
• Suitable for class A, B, C fires.
• HFC-227ea is an engineered and Pre-engineered computer designed to protect specific hazards.
• HFC-227ea clean agent system you assured of fast, efficient, environmentally safe fire extinguishment.
• Recognized and certified by the top independent listing & approval parties NFPA, UL, FM, U.S.EPA.
NOVEC-1230 ea
• NOVEC-1230 system cylinder valve assemblies are equipped with pressure differential high flow rate valves in order to meet therapid discharge time of 10 seconds a specifies in NFPA2001.
• NOVEC-1230 has wide filling range from 23lbs to 850lbs allowing for varied head outlets ranging from 1 to 3 >
• NOVEC-1230-cylinder head valves have been designed to be actuated electrically, pneumatically or mechanically to make
it suitable for different design applications.
• 3M™ NOVEC 1230™ is colorless, electrically non-conductive fluid chemical known as fluroketone FK- 512-1-.
• 3M™ NOVEC 1230™ a breakthrough in fire protection science has a 20-year blue sky warranty against regulatory bans
• 3M™ NOVEC 1230™ offers a unique combination of safety low environmental impact and extinguishing performance.
Thermo-Act
Thermo-act systems are the advanced technology of automatic fire suppression systems. The systems provide a self-activating suppression system that suppresses fires in seconds. They are simple design and installation with low maintenance, highly cost effective and reliable. The electrical or pneumatic sources shall not be required to our thermo-act systems. The systems can be used in the presence of an increased risk of fire. Thermo-act systems utilize fire flexible tube for fire detection. Thus, the fire detection and extinguishing system is not required to detect and discharge.Thermo-act systems can be designed with commercial available agents including clean agent, wet chemical, foam, and dry powder. The systems may be arranged as:
Direct System :
Thermo-act direct system for low pressure agent as shown below uses the flexible tube as both the detection device and extinguishing discharge system. In case of fire, the section of tube most exposed to heat will rupture forming a discharge nozzle. The suppressant agent is then completely released due to pressure drop in the tube.Indirect System :
Thermo-act indirect system for low pressure agent as shown below uses the tube as a fire detection device only, the fire suppression agent is delivered through a special copper or stainless steel tubing system, once the tube ruptures due to heat exposure, the drop in pressure activates the indirect valve to direct the flow of suppression agent to diffuser nozzles via a fixed tubing system, this system is usually used in large areas.FIREPRO SYSTEM
• Most Number of Certificates, Listings, Approvals Test Report• Non Pyrotechnic - Patented Technology
• Electrical and Thermal Activation - Solid to Gaseous Aerosol Phase
• Extinguishes Fire Chemically Without Removing Oxygen
• “Total Flooding” Approach
• Easy Design Calculation
• Environmental & Eco Friendly
• No Corrosion
• No Effect On Equipment Operation
• Safe, Non Toxic
• No Pipework, Pressure Cylinders, No Filling
• Highly Space Saving, Much Lower Installation/Maintenance Costs/Time
• Solutions For Most Applications
• Worldwide installations in Over 75 Countries